image/svg+xml The SwitchMed programme is funded by the European Union image/svg+xml image/svg+xml

This practice from a potato frying company, highlights how energy and mass balance lead to the identification of saving opportuninties. It was possible to reuse the waste vapor released from the fryer for heating the blancher water thus reducing the steam needed in the blancher.